Helmholz Benelux introduces Softing’s aplSwitch Field

Helmholz Benelux introduces the aplSwitch Field from Softing Industrial: a 16-port Ethernet-APL Field Switch for process automation. The switch provides a direct connection between Ethernet-APL field devices and higher-level Industrial Ethernet networks, and is designed for use in potentially explosive atmospheres.
What is Ethernet-APL?
Ethernet-APL stands for Ethernet Advanced Physical Layer and brings Ethernet communications directly to field level in the process industries. Data and power are transmitted over a single two-wire connection. Ethernet-APL has been specifically developed for process automation and enables fast, digital communication with field devices, including in potentially explosive atmospheres.
Easy migration from PROFIBUS PA to Ethernet-APL
A key advantage of the aplSwitch Field is the ability to migrate existing PROFIBUS PA installations to Ethernet-APL in stages.
Alongside the standard aplSwitch Field, the aplSwitch Field PA is available for this purpose. This version features an integrated PROFINET proxy and supports both Ethernet-APL and existing PROFIBUS PA field devices on a single switch.
This means existing PROFIBUS PA infrastructure does not have to be replaced all at once. Existing field devices can remain in service while new Ethernet-APL devices are gradually added to the installation. This makes the aplSwitch Field PA particularly suitable for retrofit and modernisation projects where existing investments need to be preserved as far as possible.

16 Ethernet-APL connections and PROFINET integration
The aplSwitch Field features 16 Ethernet-APL 2-WISE spur ports and can be integrated into Distributed Control Systems and Asset Management Systems.
The switch supports PROFINET and Media Redundancy Protocol (MRP), enabling redundant ring topologies. Extensive diagnostic functions are available for commissioning and maintenance via PROFINET and a local display.
The aplSwitch Field is suitable for integration with systems from Siemens, Emerson and ABB, among others.
Suitable for potentially explosive atmospheres
The aplSwitch Field is designed for installation in Ex Zone 2. Field devices located in Ex Zone 0 and Zone 1 can be connected via the switch.
The switch supports Two-Wire Intrinsically Safe Ethernet (2-WISE) and supplies connected Ethernet-APL field devices with intrinsically safe power.
The standard version supports both Power Class A and Power Class B. This means Ethernet-APL field devices with higher power consumption can also be connected. The switch is housed in an IP30 enclosure.
With the aplSwitch Field, Helmholz Benelux offers a solution for companies looking to bring Ethernet communications down to field level while modernising existing PROFIBUS PA installations in a controlled manner.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeReliable industrial network connectivity
- SubjectControl & networks