Control & networks

Standard and safety communication in one smart module

Text Murrelektronik en Evi HussonImage Murrelektronik

Slimmer automatiseren: één module die standaard-, safety- én IO-Link-functies samenbrengt.
Slimmer automatiseren: één module die standaard-, safety- én IO-Link-functies samenbrengt.

Making machine and system automation simpler, faster and more cost-effective

Simplifying complex configurations is what Murrelektronik’s new MVK Fusion CIP Safety module does. The Ethernet/IP CIP Safety module combines three fundamental installation technology functions: digital standard sensors and actuators, digital safety-related sensors and actuators, and IO-Link. This offers attractive possibilities for a wide range of automation applications.

Making industrial automation as simple, well-designed and cost-effective as possible with smart solutions is Murrelektronik’s speciality. With the MVK Fusion fieldbus module, the company aims to standardise modular processes. The latest addition to the range is the MVK Fusion CIP Safety. This 3-in-1 solution combines three key installation technology functions: digital standard I/O, digital safety I/O and IO-Link. This means fewer fieldbus modules are needed for each modular unit, in the best case just one. Installation is therefore simpler and faster.

Compact and powerful: fewer modules needed, more flexibility in every installation.

Easy configuration

MVK Fusion CIP Safety significantly simplifies the configuration of safety-related sensors and actuators. Parameters can easily be set in the controller manufacturer's engineering tool. No special tool is needed to transfer the SNN (Safety Network Number) to a new device. This saves time and reduces stress by eliminating the possibility of incorrect entries.

Safety output (FDO)

The MVK Fusion CIP Safety module has various M12 ports. X3 is a safe digital output. It is a powerful and flexible solution for a range of applications, with the following features: up to 2 A per channel, one or two safety outputs per I/O port, configurable output behaviour (P-P, P-M, P-P-M), control of different types of actuators, including double valves, and high diagnostic coverage through a dark test.

Safety input (FDI)

The safe input ports X0, X1 and X2, each with two channels, register signals from typical safety sensors up to the maximum performance level e. The ports are short-circuit and overload-proof and have a robust 24 VDC/700 mA power supply. Parameters such as discrepancy, input delay and sensor valency can be configured, and individual test pulses are possible for detecting peripheral faults.

IO-Link

IO-Link ports X6 and X7 enable the cost-effective integration of complex sensors and actuators into the fieldbus system and extend digital standard signals. Up to 32 additional DIOs can be added using IO-Link hubs. Safe shutdown of IO-Link devices up to performance level d is also possible with the class B IO-Link port X7.

For every environment: robust, reliable and ready for demanding conditions.
Configure faster: set safety parameters easily and without errors.

DIO

The digital ports X4 and X5 offer maximum flexibility and efficiency. They can be used as inputs or outputs. The outputs deliver up to 2 A per channel. An input delay of 1 to 15 milliseconds can be configured. The port is protected against reverse polarity, short circuits and overloads.

Ethernet and power

For communication with the controller and daisy-chaining the fieldbus, the MVK Fusion CIP Safety has M12 D-coded Ethernet ports. The module is equipped with M12 Power L-coded connections for the power supply. Power can be daisy-chained via the XD2 port up to a maximum of 16 A.

Demanding environments

The MVK Fusion CIP Safety is suitable for demanding environments. It has a robust, moulded metal housing and is IP67-certified, resistant to shock and vibration, and can withstand temperatures from -30 to +60°C.

Adapters

Various adapters are available to simplify the connection of devices with safety and standard signals. Configurable sourcing bipolar safety outputs can be used for Safe Torque Off. Configurable single or redundant safety inputs are suitable for standard safety contacts or OSSD devices. Operating many devices, such as emergency stops with reset buttons or interlocks, requires a combination of safety and standard signals.

Safety configuration in just a few clicks

In short, MVK Fusion CIP Safety significantly simplifies the configuration of safety-related sensors and actuators. It makes complex configurations simple, perfectly matching Murrelektronik’s philosophy: making machine and system automation simpler, faster and more cost-effective.    

Een zakelijke vraag aan Murrelektronik? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.