News

Motors for hazardous areas are no longer exempt

Motors for hazardous areas are no longer exempt

Strict regulations apply to hazardous areas too. Even so, changes to the rules can cause disruption. Marek Lukaszczyk, Marketing Manager for Europe and the Middle East at WEG, a leading global manufacturer of motors and variable speed drives, explains the changing regulations for motors used in hazardous areas and how the new energy-efficiency requirements can deliver major financial benefits.

More than 8 billion electric motors are in use in Europe, consuming around 63 per cent of the electricity generated across the continent. Until recently, some of these motors, including those designed for hazardous areas, were exempt from energy-efficiency regulations, but that is about to change. The latest regulatory amendment covers a wider range of motors and, for the first time, includes variable speed drives, which must meet a higher efficiency standard from July 2021.

In 2009, the European Commission introduced minimum energy performance standards (MEPS) under Regulation EC 640/2009. The regulation required motors rated between 0.75 and 375 kW to comply with the international standards set by the International Electrotechnical Commission (IEC) for three-phase motors operating at a fixed speed. IE1 denotes standard efficiency, IE2 high efficiency, and IE3 is used for motors with the highest efficiency level.

Regulatory amendments in 2016 required electric motors to achieve an energy efficiency class of at least IE3, or IE2 if used with a variable speed drive (VSD). The regulation has led to major improvements in motor energy consumption, partly thanks to advances in motor design and materials.

It is no surprise, then, that the electric motor market responded quickly to the regulatory changes by switching to more efficient motors. IE1 and below, which accounted for 80 per cent of the European market in 2009, had fallen to just 17 per cent by 2016. Over the same period, the market share of IE3 premium-efficiency motors rose from 0 per cent to 29 per cent. Good news for the planet, and cost savings for end users.

Electric motor design has been improved to maximise energy-saving opportunities. The European Commission’s Ecodesign Committee has now approved a new, stricter version of the ecodesign requirements, which will come into force on 1 July 2021.

Previously, the regulations applied only to three-phase motors rated from 0.75 kW to 375 kW; motors outside this power range were excluded. From 2021, this will no longer be the case. Under the forthcoming regulations, all new 2-, 4-, 6- and 8-pole motors rated from 0.75 to 1000 kW must meet the IE3 efficiency requirements. Under the old regulations, an IE2 motor could be used if it was controlled by a VSD, but this will no longer be allowed. Motors rated from 0.12 to 0.75 kW must meet IE2 requirements.

Motors for special applications, such as explosion-proof or fire-resistant motors, were exempt from the previous regulations as a precaution, given the higher-risk environments in which they are used. From July 2021, new ATEX motors added to the supply chain must meet the IE3 efficiency standard or higher. The only exception is Ex eb increased-safety motors, which must meet at least the IE2 efficiency level by 2023.

WEG has offered energy-efficient motors for hazardous areas for decades. However, without a requirement to use high-efficiency motors in hazardous areas, some companies opted for less efficient motors, possibly because of their lower purchase price.

WEG’s motors for hazardous areas meet the new energy-efficiency standard, and have done so for years, well before the regulatory changes were announced. In fact, WEG’s range of IE3 motors for hazardous areas is manufactured in accordance with IEC standards.

WEG also offers IE4 super-premium-efficiency motors for both safe and hazardous areas. This puts the company in a strong position ahead of the 2023 requirement for motors used in safe areas, rated between 75 and 200 KW and not fitted with a brake or intended for hazardous areas, to meet the IE4 efficiency class.

In energy-intensive industries such as chemicals, pharmaceuticals, and oil and gas, thousands of motors often run 24 hours a day. Even a small improvement in efficiency, multiplied across a huge number of motors and operating hours, can significantly boost companies’ profit margins.

Depending on the application, energy costs account for 95 to 97 per cent of the total lifetime cost of electric motors. Investment in energy-efficient variable speed drives and motors, even if it is not voluntary, usually pays for itself very quickly. Take WEG’s W22Xd series of IE3-class explosion-proof motors, for example. Their lower operating costs can reduce costs by 20 to 40 per cent compared with conventional drives.

If you own one of the 8 billion electric motors in Europe and need to upgrade a low-efficiency motor used in a hazardous area, contact WEG for a straightforward quality upgrade.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectNews
Share this article

Advertisement

Follow on Industrial Automation Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.