Power supplies are crucial to machine uptime

Power supplies are crucial to machine uptime

Machine uptime is a key issue in industry. The power supply plays an important role. Understanding the performance indicators that determine a power supply’s reliability makes it possible to take timely action and carry out maintenance. One type of power supply that helps take this step towards predictive maintenance is the new CliQ VA series from Delta, a market leader in power supplies, available from A&C Solutions.

Predictive maintenance is a strategy that ensures maintenance is only carried out when it is genuinely needed. This strategy offers significant benefits: easier planning, no unexpected breakdowns, lower costs, less inventory… In short, predictive maintenance maximises machine uptime at lower cost. The major benefit is the ability to respond fully to your customer’s needs, giving their experience of your service a huge boost. Correctly interpreting the performance indicators that determine the power supply’s reliability is crucial to achieving this. Two important indicators are MTBF and service life.

The graph above clearly compares the statistical failure rate, MTBF and service life across a number of different applications. A missile has a short service life in operation. Its task is often complete within 5 to 10 minutes. The probability of failure during this short period must be very low, resulting in a very high MTBF.

MTBF

MTBF (Mean Time Between Failures) indicates the average frequency with which a power supply fails. The failure rate, the frequency at which faults occur over time, is represented by the symbol λ (lambda). MTBF is the average time between failures, measured in hours, and is a prediction of a power supply’s reliability. MTBF = 1 / λ (failure rate). In practice, MTBF is used more often than failure rate. We take 1,000 power supplies and run them for 2,000 hours. This gives 2 million unit-hours. If four units fail during this period, the failure rate is four failures / 2 million unit-hours = 2 x 10-6 per hour, or
2 ppm per hour. MTBF = 1/2 x 10-6 per hour, which gives 500,000 hours, a much clearer figure. It is important to understand that the failure rate / MTBF relates to statistical failures that apply from the first hour of operation. Failures caused by manufacturing or design are not taken into account, as the manufacturer must eliminate these through testing (burn-in). Age-related failures are not taken into account either. Higher temperatures have a very negative effect.

Service life

Service life does not refer to statistical failures during normal operating time. It refers to the point at which components are no longer usable due to wear. The components that have the greatest effect on a power supply’s service life are the electrolytic capacitors. The electrolyte they contain dries out or evaporates over time. A power supply’s service life therefore depends heavily on the type of electrolytic capacitor used in its design, as well as the operating temperature. Every 10 °C increase halves the service life.

Bathtub curve

Interpreting MTBF values

There are many ways to calculate MTBF values in particular (MIL HDBK 217 F, SN 29500, Telcordia SR-332). The results vary widely depending on the calculation method and the definition of operating conditions. When assessing an MTBF value, it is therefore important to know both the calculation behind it and the equipment’s operating conditions (stress factors). For high-quality industrial power supplies, both MTBF and service life are important. The power supply must last a long time with as few failures in between as possible. An industrial power supply can be considered the beating heart of a machine or business process. Unnecessary downtime brings machines to a standstill and disrupts production, resulting in enormous costs.

Traffic Control Systeem met app besturing van SIGMATEK.

Comparison of the reliability values for the DELTA CliQ VA 24Vdc, 10A under different conditions

Efficient monitoring and maintenance

One power supply that supports predictive maintenance is the new CliQ VA series from Delta, a market leader in power supplies. The CliQ VA series features an LCD display that informs and alerts users through three functions. In display mode, users can easily scroll through values such as output voltage, output current, the expected service life of the electrolytic capacitor and the internal temperature. The maintenance alarm can be set in advance to warn users before the electrolytic capacitor reaches its expected service life. The display also shows a fault mode, making it quick to identify the cause of any deviations.   

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectNews
Share this article

Advertisement

Follow on Industrial Automation Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.