Process & instrumentation

Dream team tackles heat and condensation

Completely different conditions prevail in the two sections of the vacuum reactor.
Completely different conditions prevail in the two sections of the vacuum reactor.

This is why conventional differential pressure transmitters have limitations when it comes to monitoring levels during the production of additives for paints and plastics. VEGA’s electronic differential pressure measurement technology, by contrast, ensures perfect safety and accurate measurement results thanks to its innovative combination of ceramic and metallic measuring cells.

BASF is one of the world’s leading producers of additives for plastics. These substances help make plastics resistant to colour fading, abrasion and heat, as well as elastic, crystal-clear and more. Under precisely defined conditions, raw materials are converted into additives through a series of chemical reactions. This takes place in a fully automated process in which every measured value is carefully monitored and recorded to ensure the correct dosage. Reliability is crucial at the Kaisten site, because the end product is an essential building block for BASF. Any downtime has far-reaching consequences. “Even the smallest problem interrupts a complex process. In practice, that means working weekends and overtime for us,” explains Marcus Stoll. He heads BASF’s Specialist Workshops EMSR. Together with his team, he is responsible for ensuring the highest possible availability.

Protecting processes from silicone oil is one of the building blocks of BASF’s efforts to achieve the highest possible safety at every process step at its site in Kaisten, Switzerland.

In the eye of the storm

Vapour pressure plays an important role in the production of these additives. The more precise the measurement, the clearer the picture of the processes and the more efficiently they can be managed. It also provides additional information on how process components can be optimised. The conditions, however, are far from easy: aggressive substances and acids that can leave deposits on the tank walls, as well as high levels of vacuum and steam. This is where VEGA pressure sensors and their reliable measurement results make the difference. BASF’s engineers previously used conventional differential pressure transmitters for this application. However, they decided to switch to electronic pressure sensors that operate without silicone oil-filled capillaries or diaphragm seals. “Choosing a system based on ceramic CERTEC measuring cells was an obvious decision, particularly because of their ability to withstand abrasive substances. Our plant has to run 24/7,” Stoll emphasises.

Marcus Stoll: “The combination works like a dream team. As far as I know, VEGA is the only supplier to offer this combination. It gave BASF a solution to two challenges.”

One solution for two extremes

The extremely robust ceramic CERTEC measuring cell was ideal for the lower section of the BASF vacuum reactor, which contains hot, aggressive solvents. Conditions in the upper section, by contrast, were completely different. Here, extreme levels of steam cause condensation in the measuring cells, which can lead to inaccuracies. The obvious solution was to use differential pressure transmitters based on metallic METEC measuring cells. Condensation and humidity do not adversely affect these measurements. “The values measured in the upper section are now, and remain, acceptable and highly accurate in all situations,” says Stoll. However, the high temperature of the solvent below could cause the measured values to drift. Resolving this called for expertise, a willingness to experiment and, above all, close collaboration between BASF and VEGA. 

A combination that makes a dream team

The surprising solution was to use an innovative electronic differential pressure measurement system that combines a ceramic and a metallic measuring cell. The two sensors measure their respective values separately and then calculate the differential pressure in the primary sensor. This is made possible by using identical electronics behind these two very different measuring cells. Stoll says: “The combination works like a dream team. And as far as I know, VEGA is the only supplier to offer this combination. It gave BASF a solution to two challenges.” 

Question about this story? Ask your question

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectProcess & instrumentation
  • CompanyVEGA
Share this article

Follow on Industrial Automation Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.