Bus systems bring simplicity to the complex world of machine safety. That may sound strange, but configuring safety systems is actually easier with bus systems than with traditional hard-wired systems. There is a bus solution for every platform. Alongside EtherCAT P with FSoE, other interfaces have been available for some time: ProfiNet with ProfiSafe and EthernetIP with CIPsafety. Each bus platform is suited to a different world of control systems. Preferences vary across Europe, North America and Asia. The MGB-Modular door locking system can be used with any of these control systems.

Thanks to the modular design of this door locking system, the bus interface is housed in just one module, known as the ‘bus module’. This determines which bus platform the door locking systems connect to. The bus module contains, among other things, the chipset for the relevant bus. The bus module is assigned an address manually using DIP switches.

The request for this new interface came from the EtherCAT user community, led by control system manufacturers. Input from both sides helped guide the development process, resulting in this latest innovation.

The Euchner MGB2-Modular EtherCAT P with FSoE door locking system:

  • Up to 4 door locking systems can be connected to one bus module.
  • There is room for 36 safety-related elements, including the 4 door locking systems (buttons, functions, etc.).
  • Every safety function achieves PL e, Cat. 4, SIL 3.

FSoE stands for Fail Safe over EtherCAT. It is a transmission protocol for safety data over EtherCAT. Under this protocol, safety data is delivered within a specified time and is unambiguous, or unique.

This bus system uses a traditional master-slave structure. It can be branched almost indefinitely, but you need to keep an eye on the maximum amount of data the bus can handle. Transmitting safety data over bus systems uses quite a lot of data, resulting in heavy bus traffic. The door locking system on an access door continually communicates its status: ‘the door is closed, the door is closed, the door is closed…’, together with its address so the receiver knows which door it is. Other safety-related messages are transmitted in the same way.

Replacing a bus participant, such as a door locking system, or expanding or reducing the system is straightforward. You only need to update the topology. Of course, this requires an authorised programmer with knowledge of functional machine safety.

Functional safety is quite straightforward, but you need to learn to look at it in a particular way. Euchner therefore provides training that explains how safety components communicate with one another. A lot has changed over the past ten years: Industry4.0, Internet-of-Things, Big-Data, etc. Yet the bus telegrams themselves have remained essentially unchanged. The training compares different communication methods. Functional safety is quite straightforward, but you need to learn to look at it in a particular way.

More information at www.euchner.nl / www.euchner.be / www.euchner.lu

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe machine design and operation
  • SubjectSensors & vision
Share this article

Advertisement

Follow on Industrial Automation Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.