Unique 3D-linearised differential pressure transmitter reduces time-consuming calibrations

Differential pressure measurement remains one of the most widely used measurement techniques in industry. This is reflected in the growing demand for DP transmitters.
This technique is certainly not outdated. With innovative solutions, leading suppliers to the process industries are responding to increasingly stringent requirements for accuracy, long-term stability and connectivity, and, above all, the functional safety of differential pressure measurement. KROHNE, a market leader in flow and level meters, introduces the Optibar DP 7060 C differential pressure transmitter, in which every measurement undergoes full 3D linearisation, a market first.
As a leading supplier of measurement instrumentation, KROHNE offers complete DP, flow and level solutions, with sizing, engineering and documentation tailored to each specific application. The new Optibar DP 7060 C differential pressure transmitter not only provides accurate differential pressure readings wherever they are needed, but also measures the static pressure in the process line. Its unique feature is that every DP measurement undergoes full 3D linearisation, and is therefore characterised across the entire operating range: measuring range +/- DP, temperature from –40 to 85 °C, and static line pressure from 0 to 160 bar. KROHNE is thus the only manufacturer to perform 100% 3D linearisation and calibration on every DP transmitter.

The measuring cell makes the difference
A new measuring cell, which is 100% linearised and calibrated, makes the difference. The starting point is a purely mechanical design with advanced monocrystalline silicon piezoresistive sensors for differential and absolute pressure, the filling process, and the linearisation of external effects caused by static pressure and temperature. In the measuring cell, the individual pressures on the high-pressure and low-pressure sides are conveyed through a diaphragm and filling fluid to the primary sensors in the fluid capsule. For a stable design and good accuracy at high process pressures and varying ambient temperatures, the effects of these factors must be eliminated in three steps: smart mechanical design, electronic compensation and linearisation. The effects of high line pressures and unexpected overpressure must also be minimised. The diaphragms are matched to the capsule’s base shape, limiting mechanical movement so that it remains within the material’s elastic properties. This prevents plastic deformation that could alter the measurement. The effect of ambient temperature is further reduced by making the capsules smaller and reducing the volume of filling fluid. The capsule is filled with precisely metered volumes of degassed filling fluid in a controlled, automated environment, and then undergoes 3D linearisation.
Full 3D linearisation
To meet more stringent requirements and tight commissioning and maintenance schedules, the capsule has three sensors for differential pressure, absolute pressure and temperature. The effects of residual static pressure and ambient temperature are linearised. To do this, mechanically prepared measuring capsules are mounted on a jig in batches and placed in a heating chamber. The capsules undergo a linearisation cycle, resulting in a 3D matrix of linearisation coefficients. These are incorporated into a correction polynomial and uploaded to the front-end electronics. This enables the amplifier electronics to provide the correct digital measured values. A second calibration is performed in the heating chamber to ensure that performance meets all specifications. After calibration, the measuring capsules can be customised to meet customer-specific requirements for HMI, communications, accessories and other functions.

Industrial processes
A number of important steps are required to ensure that a conventional DP transmitter operates correctly in an industrial process. After mechanical installation, the typical zero measurement is performed and the range is calibrated. In applications with high static pressure, the transmitter is isolated from the process for calibration. The transmitter must also be reverified regularly. KROHNE’s 3D-linearised differential pressure transmitter significantly reduces the number of time-consuming calibrations. It also needs to be reverified less frequently, lowering the TCO. The internal absolute pressure sensor and full 3D linearisation prevent deviations caused by regularly changing line pressures, eliminating the need for periodic readjustment. Standardised process connections, quick installation routines in twelve languages, various mounting options and a modular HMI speed up and simplify installation. Bluetooth communications make commissioning and inspection child’s play.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeSmarter measurement and inspection
- SubjectSensors & vision



















